Coleman Furnace 6 Blinks: Pressure-switch cycle lockout

Coleman furnace code 6 Blinks means the pressure switch opened four times during one heat call, causing lockout on the supported control family. Confirm the model number and diagnostic chart inside the furnace door before replacing parts.

Reviewed August 2026
Furnace control · fault
6 Blinks
Pressure-switch cycle
COLEMANBlink code sequences on the integrated furnace control

What does Coleman code 6 Blinks mean?

Coleman furnace code 6 Blinks means the pressure switch opened four times during one heat call, causing lockout on the supported control family. Confirm the model number and diagnostic chart inside the furnace door before replacing parts.

What causes Coleman code 6 Blinks?

  • A blocked intake or exhaust vent
  • A restricted condensate drain or pressure hose
  • A weak inducer motor or pressure switch

Can I troubleshoot Coleman code 6 Blinks?

  1. With the furnace off, check outdoor intake and exhaust openings for snow, ice, leaves, or nests.
  2. Replace a visibly dirty air filter, restore power once, and note whether the code returns.

How much does Coleman code 6 Blinks cost to fix?

A pressure switch replacement typically costs between $175 and $900 nationally.

Typical repair cost
$175$900pressure switch replacement
Where the money goes
Part $30$120Labor $55$870Typical labor time: 1–2 hrs

When should I call a technician?

Call a technician if the vent is clear and the pressure-switch code returns; combustion-air testing requires instruments.

Sources and model scope

Fault codes vary by model and control board. Confirm the diagnostic chart inside your furnace panel or the official manual before acting.

Scope used here: Johnson Controls integrated furnace controls using the documented 1–12 red-flash table.

Compiled by Warmlo Editorial · Reviewed August 2026